Abstract

Abstract The article presents the results of validation of static calculations carried out for a monolithic rectangular tank with walls of trapezoidal cross-section. Static calculations were made with the use of software based on the finite element method (FEM) and the finite difference method (FDM) in terms of energy (including spatial static work of the tank). Validation of the results was conducted on a concrete tank model using an innovative measurement tool, i.e. a coordinate measuring arm with a touch probe.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have