Abstract

Through the indoor waterproof test, the water pressure resistance performance of the waterproof system formed by setting embedded grouting pipe in the middle of double water swelling sealants was studied to ensure that the station pipe joint could meet the operation requirements. The results show that there must be enough distance between the outside sealant and the edge of the pouring concrete, otherwise the new and old concretes cannot be poured tightly; after swelling, the water pressure resistance of sealants is improved in the range of 0-0.55 MPa, with individual differences; the two kinds of slurries have obvious influence on the improvement of water pressure resistance, but the improvement effect of waterborne epoxy slurry is better than that of polyurethane slurry.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.