Abstract

The air disinfection efficacy of upper-room 222 nm Far-UVC was experimentally investigated in a real-size chamber under well-mixed air conditions. Two bacteria (Escherichia coli, Staphylococcus epidermidis) and two bacteriophages (MS2, and P22) were selected for the test. The study considered different lamp source arrangements, including single and double sources, stationary and rotating operating modes, and an overlapping mode with a 45° irradiation angle. A numerical view-factor model was developed to analyze the irradiance distributions. Four irradiation angles, 30°, 45°, 60°, and 90°, were chosen. The results show that the lamps operating with an irradiation angle of 45° provide the highest chamber-averaged irradiance. This suggests an optimal irradiance level for a given room dimension, as inferred from the view factor model. Experimental results indicated that the overlapping mode with a 45° irradiation angle consistently outperformed both the stationary mode and rotating mode in disinfection. This can be attributed to the higher chamber-averaged irradiance, which is also supported by the numerical model predictions. The increment ratios ranged from 14.9 % to 42.9 % compared to the stationary mode. The susceptibility constants of Escherichia coli, Staphylococcus epidermidis, MS2, and P22 were measured as 0.572 m2/J, 0.099 m2/J, 0.060 m2/J, and 0.081 m2/J respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.