Abstract
In order to study the flue gas velocity distribution and pressure drop characteristics inside wet desulfurization Tower, experimental study has been carried out. Flow model is built with geometric scale of 1 / 12 , flue gas velocity ratio of 1 / 1 and different gas entrance angle as 12°and 7°. Experiment result shows that Spray liquid droplets made gas more evenly; The evenness of gas velocity distribution is very poor with very low gas load (<35%);The pressure drop in tower increases with increase of sprayer and increases with increase of gas load; The evenness of gas velocity distribution becomes poor and the pressure drop increases when gas inlet angle changes from 12°to 7°.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.