Abstract

In the 200 m high temperature superconducting (HTS) cable test facility at Chubu University constructed in 2010, a three-layer structure of the tapes in the cable is employed for obtaining the high current capacity up to 2 kA. Previous study shows that the critical current is affected by the layout of the tapes such as gaps and the current feeding mode. In the stacked tape conductors, the critical current of BSCCO tapes shows strong dependence on the current feeding directions between the tapes. The critical current is improved when the opposite-direction current is applied to them and degraded for the same-direction current feeding mode because of strong magnetic field interaction between them from the transport current in each tape. This paper presents the measurements of the critical currents of a BSCCO tape in the stacked conductors with the ferromagnetic materials. By using the ferromagnetic materials surrounding the tapes, self-field of HTS tapes is affected and their critical currents are improved by more than 10%. Ferromagnetic shunt effects on the critical current of HTS tape are reported through the magnetic field analysis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.