Abstract
Ventilation effectiveness in aircraft cabins is a critical factor for minimizing the cross-contamination of airborne pathogens exhaled by the passengers. In this study, a full-scale section of a Boeing 767 aircraft cabin containing thirty five mannequins was used for evaluating the ventilation effectiveness and characterizing the air distribution. Each mannequin was attached with a body heater and an outlet of carbon dioxide to simulate breathing. A set of experiment trials was conducted to measure the local mean age of air and the ventilation effectiveness factor (VEF) at the breathing level of the passengers. Carbon dioxide was used as the trace gas to determine the local mean age of air and the VEF. The air velocity profiles measured using a volumetric particle tracking velocimetry (VPTV) system was used to generate the airflow patterns and investigate the underlying mechanism affecting the local mean age of air and the VEF. In addition, measurements were conducted at different air supply rates to examine its effect on the ventilation performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.