Abstract

In order to solve damage detection problem of transmission tower, a damage index based on inter-storey stiffness and cepstral distance is presented. First, transmission tower model is established and the tower is divided into six sub-structures. Thus, we only need to identify the sub-structure location where the damaged rods are included. Then, autoregressive model is introduced, the cepstral distance between autoregressive models under damaged and undamaged states is given, and a damage index based on inter-storey stiffness and cepstral distance is proposed. Finally, the experiment of transmission tower model is conducted to evaluate the effectiveness of detecting the damaged layer of transmission tower. The analysis results of the experimental signals show that the damage index based on inter-storey stiffness and cepstral distance is an available method for damage detection of transmission tower, and the damage feature can be well extracted with the damage index.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.