Abstract
The galvanic corrosion behaviours of carbon fibre composite coupled to aluminium are studied when the galvanic couple is just immersed in artificial seawater or connected to a closed electric circuit. The effects of grinding condition, concentration of artificial seawater, applied torque, applied current and experimental time are studied. The roughness average, weight gain of carbon fibre composite and weight loss of aluminium are investigated as a function of the above variables. The results show that the applied current can accelerate the galvanic corrosion greatly. With improving grinding condition and increasing applied torque, the roughness average, weight gain of carbon fibre specimen and weight loss of aluminium specimen increase, reach maximum and then decrease. With increasing concentration of artificial seawater, applied current and experimental time, these measured values increase. Corroded surface morphology is also investigated using scanning electron microscopy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.