Abstract

This study explores the aerodynamic characteristics of a ducted contra-rotating lift fan for vertical/short takeoff and landing application by means of force, pressure, and flow field measurements. The effect of rotating frequency and contra-locomotion on the force generation was examined using a miniature six-component force sensor. Additionally, for the sake of considering the ground effect, the flow field at the exit was investigated using high-response pressure measurement. Results revealed that the lift shows a quadratic generation trend on increasing the r/min where the inherent unsteady flow contradicts the conventional quasi-steady model of propeller. The contra-rotating mechanism can significantly augment the lift while still being lower than double single rotors. The unsteadiness of the contra-rotating rotors is quite obvious where two high-pressure regions are revealed and rotate. When the lift fan approaches the ground, the lift will be augmented significantly due to the surplus of the wake jet.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.