Abstract
Experimental investigation of heat transfer and friction factor characteristics of thermosyphon solar water heater with helical screw tape of various twist ratios(Y=3, 4, 5 and 6) has been studied. Compared to other twist ratio, the minimum twist ratio 3, offers higher Nusselt number, friction factor and Thermal performance. The average Nusselt number, friction factor and thermal efficiency for helical screw tape collector with minimum twist ratio 3 are 13.86, 0.111 and 63.62% respectively. Whereas the increasing twist ratio decreases the above performance. The heat removal factor for screw tape collector with twist ratio 3 has 54.4% higher than plain tube collector. Correlations developed for friction factor and Nusselt number has been verified and deviation falls within ±13%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Asian Journal of Research in Social Sciences and Humanities
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.