Abstract

Stark broadening parameters of 20 Ar II lines from the 4s-4p and 3d-4p transition arrays and of 19 Xe II lines from the 6s-6p and 5d-6p transition arrays were measured. Additional broadening mechanisms other than Stark effect were taken into account. A wall stabilized stationary cascade arc served as plasma source. Electron densities were determined with high precision from independent measurements with a two-wavelengths Michelson interferometer. The results are compared to experimental data from literature and semiempirical calculations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.