Abstract

In order to know the characteristic of heat transfer performance on train body, the DRH-300 instrument was used to investigate equivalent thermal conductivity coefficient of hollow-structure aluminum of bullet train “Fuxing”. It was analyzed that the same hollow-structure aluminium was under different temperature difference; while the equivalent thermal conductivity coefficient with different position of train body was under same temperature difference. The experimental results showed that the equivalent thermal conductivity coefficient of the same hollow-structure aluminum was the same under different temperature difference; the impact of the equivalent thermal conductivity coefficient on different hollow-structure aluminum was different under the same temperature difference. It showed that heat convection in the hollow was tiny, compared with heat conduction. On the practical application, the reasonable structure was selected in accordance with practical needs, so as to reduce heat transfer and energy consumption of train.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.