Abstract

7-aminocephalosporanic acid (7-ACA) is the key intermediate powder to product cephalosporin. The ignition temperature test device (NU-TC1000) for dust cloud was used to test the minimum ignition temperature of 7-ACA dust cloud. When the dispersion mass of 7-ACA dust is 0.8g, the minimum ignition temperature of dust cloud is 496°C. The minimum ignition temperature increases first and then reduces with the increase of dispersion mass. When 7-ACA and acetone are mixed in the ratio of 1g 7-ACA plus 0.75ml acetone and the dispersion mass of mixture sample is 0.6g, the minimum ignition temperature of dust cloud is 400°C. Experimental results show that the minimum ignition temperature of dust cloud decreases markedly by adding acetone into 7-ACA dust. How to set powder has a quite influence on the results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.