Abstract

In this work, R1234yf is tested in an air-conditioning system as a proposed alternative to R134a. The system is tested at 30, 35, 40, 45 and 50[Formula: see text]Hz evaporator fan frequency to cool the air entering into the evaporator section at a fixed temperature of 35∘C. The system is charged with 600, 700, 800, 1000 and 1200[Formula: see text]g of each refrigerant. The charge mass of 800 grams gives the best performance for both refrigerants. Also, R1234yf has higher COP, exergetic efficiency, second law efficiency, and lower compressor power consumption. Both refrigerants operate at a moderate range of compressor discharge temperature of 85∘C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.