Abstract

This paper aims to present the influence of anode catalyst supports, current collector open ratio, liquid electrolyte layer incorporated membrane, and methanol concentration on the passive Direct methanol fuel cell (DMFC) performance. Current collectors with three different opening ratios of 45.40%, 55.40% and 63.05% were considered in the present study. For the three current collectors, the fuel cell is operated with diluted methanol solution (concentration varied from 1 to 5 M) as the anodic fuel. The experimental results showed that the current collector with 55.40% open ratio at 3 M of methanol concentration produced the MPD compared to the other two open ratios. A liquid electrolyte (LE) layer was inserted in between the two half MEAs to recuce the methanol crossover. It was noticed that the LE-DMFC gave the best performance with all the three current collector having different opne ratios. Similarly, the effect of two anaode catalyst layers was also studied. From the experimental results, it was noticed that the fuel cell performance improved by using the MEA with two layers of anode catalyst of Pt-Ru/Carbon black + Pt-Ru/C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.