Abstract
The outlet conditions of supersonic compressor rotors designed for very high total pressure ratios can be highly supersonic (impulse rotors). Then the following stator blade row has to build up high static pressure ratios at supersonic inlet conditions. This paper describes part of a research work which should answer, if it is at all possible to realize such high static pressure ratios in a cascade. Cascades with convergent-divergent blade passages were designed and optimized by boundary layer calculations. In a first step no flow turning was incorporated in the blade sections. A three-shock-type cascade was found to be an optimum design The wind tunnel measurements resulted in static pressure ratios of the order of 6 and total pressure ratios of 0.77 at inlet Mach numbers of 2.2. In a second step the flow turning to axial direction was realized. For that two types of cascades were built and tested. One was a tandem type cascade and the other a single row cascade. The experiments at inlet design conditions resulted in static pressure ratios of the order of 6.5 and total pressure ratios of 0.72.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.