Abstract

Research on Stirling type Pulse Tube Cryocooler (PTC) is focused on achieving lower temperatures by cascading the stages or by multi-staging. Multi-staging can be done either by gas coupling or by thermal coupling of the stages. In the thermal coupling option, either a two stage cooler can pre-cool a single stage PTC to reach lower temperatures or a single stage PTC can cool a two stage PTC. In the present work, both these configurations are tested experimentally keeping the same two stage PTC. In case-1, the two stage PTC is used as a pre-cooling stage while in case-2, the single stage PTC is used as a pre-cooling stage. Length of the single stage is required and to be increased to match the two stages PTC for effective thermal coupling in case-1. The lowest temperature achieved in case-1 is 50.07K where as in case-2 the lowest temperature achieved is 19.61K at 17bar charge pressure and 68Hz frequency. The pressure drop in both the PTCs is compared to analyze the difference in performance.