Abstract

Link-to-column connections in eccentrically braced frame should transfer large shear and moment developed in a fully plastic and strain hardened link. Moreover, the connection should allow the link to undergo large plastic rotations. It was observed in previous studies that link-to-column connections are failed before achieving the plastic link rotation capacity. Design of link-to-column connections in seismic-resistant eccentrically braced frames is still an unresolved problem. In this paper, experimental tests are carried out on long link-to-column connections. T-stub connections are used for connecting the link to column. The test parameter is the strength of connection by changing the connection details. The results of the tests indicate that the proposed connections can successfully achieve the desired rotations without any strength loss.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.