Abstract

An experimental investigation of a high power millimetre wave pulse sensor is presented. Two groups of sensors with a ∞at frequency response were fabricated according to results of the optimisation. The frequency response and voltage standing wave ratio were measured and compared with results of the electrodynamical simulations. The largest measured sensitivity variation of the best sensors within waveguide frequency range was §8%. The reasonable agreement between measured and simulated values of the sensitivity was obtained.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.