Abstract

Heat transfer results for subcooled and saturated inverted annular film boiling (IAFB) obtained from a 7×7 rod bundle during transient reflood are presented in this paper. The test section consists of heater rods of 9.5-mm diameter and 12.6-mm pitch arranged in a square array. Flooding rates considered are 0.076 and 0.152 m/s, pressure varied from 138 to 414 kPa, and inlet subcooling up to 83 K. Evaluation of the data includes estimation of the local void fraction and Nusselt number during IAFB as well as in the inverted slug film boiling (ISFB) regime, which occurs when the inverted annular liquid column disintegrates. Experimental heat transfer results are compared with several film boiling models, and a new correlation for the Nusselt number is proposed for the IAFB and ISFB regimes. Predicted Nusselt numbers using the new correlation deviate from the experimental data by an average error of 15% and root-mean-square error of ∼30%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.