Abstract
ABSTRACT The microstructure and mechanical properties of the hot rolled steel depend on the laminar jet cooling control on the runout table. An experimental and numerical study of the heat transfer during water jet impingement cooling of a hot steel plate (600 to 900°C) is presented. The effects of plate temperature upon the heat transfer were analyzed by the inverse heat conduction method that provided the heat fluxes on top surface from measured temperatures into the plate. Rewetting (liquid-solid contact) occurs on surface above 880°C. Higher initial temperatures enlarge the heat flux, but delay the onset of the rewetting and the advance of rewetting front radius (Rwet). Heat transfer coefficient (HTC) increases as surface temperature decreases. The size of the non-symmetric effective jet cooling zone depends on strip speed. Correlations to predict HTC and Rwet have been proposed. Results will contribute for enhancement of fast cooling system in hot strip mill.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.