Abstract

Targeted alpha therapy with radionuclides undergoing multiple alpha-particle decays is a promising method of nuclear medicine. To study the effectiveness of alpha versus beta emitters, survival of DU145 prostate cancer cells exposed to 223Ra or 177Lu was assessed. Per decay, the cells were much more sensitive to the alpha than beta emitter. However, per unit dose the sensitivities would be comparable, contrary to the well-known evidence, if the decay energy were deposited within the sample completely and homogeneously. Measurements by Timepix detectors showed about three times higher counts of alpha particles above than below the sample. After the first alpha decay of 223Ra to 219Rn, this gas likely moves upwards and its subsequent three alpha decays occur in the upper part of the sample. Correct estimation of absorbed dose is a critical issue when analysing in vitro data and when translating their results to clinical applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.