Abstract

The seismic response of suspended ceiling systems that were shaken at the University at Buffalo; University of Nevada, Reno; and E-Defense facilities is critically assessed in this paper. After presenting a brief description of each experiment, the most repetitive damage observations in all experiments are discussed. Fragility curves are developed for ceiling perimeter connectors, supporting elements, and overall performance of ceiling systems by using 346 combinations of ceiling configurations and shake intensities. The key findings of these curves are the insufficient support of the 7/8-in. wall angles, unconservative code design capacity of connections for supporting elements, and early damage of ceiling systems because of ceiling-piping interaction. Acceleration amplification factors of ceiling systems with respect to suspending floor are computed. The amplification factors prescribed by the code were found to be unconservative due to the pounding of panels to the ceiling grids and deck vibration in a vertical direction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.