Abstract

Background: The purpose of EUV pellicles is to protect the surface of EUV lithography masks from particle contamination. It is important to ensure that the optical characteristics of the pellicle membrane do not critically affect the reticle image quality. Aim: We want to verify the possibility to integrate pellicle inspection and characterization capabilities in reflective-mode EUV mask scanning microscope (RESCAN), our actinic mask inspection platform based on coherent diffraction imaging. Approach: We studied the impact of a few selected EUV pellicle prototypes on the quality and the contrast of the reticle image obtained with RESCAN. Results: We measured the scattering distribution of the pellicles, and we correlated it with the mask image contrast and fidelity. We also detected the presence of a 6.5-μm-diameter fiber on the pellicle surface. Conclusions: We demonstrated that RESCAN is suitable for through-pellicle actinic mask inspection and can be also used to characterize and monitor the pellicle quality.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.