Abstract
This paper presents an experimental efficiency comparison study between two different direct ac–ac converter topologies; a direct matrix converter and an indirect matrix converter. The evaluation is performed under variable load conditions using both discrete silicon isolated gate bipolar transistor and silicon carbide MOSFETs working at power levels up to 9 kW. Each loss measurement is carried out using two power analyzers; one placed at the input and one at the output of the converter under study. To facilitate this measurement, an output filter was necessary in addition to the normal input filter. Both converters are modulated using the same traditional symmetrical space vector approach and feature an identical input/output filter design.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.