Abstract

This work presents an experimental approach to the direct determination of the sub-grid scale scalar flux used in Large Eddy Simulation (LES). Two non-reacting jet-flow configurations were examined, one with the jet temperature similar to the ambient air temperature and one preheated jet. Hence data were obtained for varying viscosities. Each case was investigated for two different, high Reynolds numbers of 17,471 and 31,714. For the measurements of mixture fraction and flow velocity field a finest resolution of almost 100 μm was achieved. Thus both the sub-grid scale scalar flux as well as the spatially filtered quantities can be obtained from the same data set. The data were acquired by the simultaneous application of planar laser-induced fluorescence (LIF) and particle image velocimetry (PIV).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.