Abstract

The interference effect on an array of electrospray emitters is analytically and experimentally investigated. An analytical model is presented to predict the behavior of the operating voltage with respect to emitter spacing in an array of emitters. The basic idea of these models is to superimpose the electric potential of individual emitters together in an array of emitters. If only one of the emitters operates and no liquid is supplied through the neighboring emitters, the potential required to form a stable cone-jet generally increases as the emitters move closer to each other due to electrical shielding. However, at very close spacing the required potential decreases. If all the emitters operate simultaneously, the operating voltage required for cone-jet spraying increases as the emitter spacing decreases; furthermore, there is no decrease in potential when the spacing is very close. The results of the analytical electrostatic interference model agree well with the experimental data.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call