Abstract
This paper is dedicated to study the experimental validation of a numerical model based on La-Fe-Co-Si layered operating near room temperature. For the purpose of this paper, a numerical simulation based on the transient energy equations is proposed for modeling the heat exchange between the multilayer material and the carrier fluid in the regenerator bed with an applied magnetic field of 1.5 T. The main findings of the simulation show a comparison between the numerical model and experimental setup including the magnetocaloric effect of La-Fe-Co-Si, pressure drop, and exergy and exergetic efficiency.