Abstract

This paper includes experimental and numerical study of the octagonal partially encased composite (PEC) columns specimens under axial and torsion loading. The major difference between them was the concrete reinforcement details. The parameters investigated in the experimental and numerical study were the type of reinforcement details, the failure mode, width-to-thickness ratio of flange, transverse links spacing and diameter. The results were presented as load-deformation curves. Numerical model was validated using finite element method and the results indicated acceptable accuracy with tests results in the form of capacity and ductility. In the analytical phase, the experimental results in the compressive loading were compared with those obtained from CSA S16-14 and EN 1994-1-1 equations. Also, the new concrete confinement factor in proportion to the web width to thickness ratio was presented to octagonal PEC columns under pure compressive load. Furthermore, different types of retrofit of cross-shaped steel column including concrete encasement, use of stiffener plates and transverse links were investigated in this research. Results revealed that concrete confinement and use of transverse links had respectively the most and the least effect on increasing torsional capacity of the specimens.

Highlights

  • Steel-concrete structures improve the seismic performance of structures and stiffness of high-rise buildings [1, 2]

  • Partially Encased Composite (PEC) columns are made out of three plates filling the gap between the flange and web is filled using concrete

  • The results indicated brittle failure of these columns in comparison to utilization of concrete with normal strength

Read more

Summary

Introduction

Steel-concrete structures improve the seismic performance of structures and stiffness of high-rise buildings [1, 2]. Taking benefit from composite sections is of high importance in construction and tall buildings industry [3]. PEC columns are made out of three plates filling the gap between the flange and web is filled using concrete. In order to prevent flanges local buckling strength from increasing, transverse links are welded to the flange tip between the flanges on equal intervals. In Europe, hot-rolled compressed standard sections are used which are inherently resistant against local buckling. The concrete casted between the flanges both provide a certain part of the column axial compressing strength and prevent column web from local buckling.

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call