Abstract
The test results of nine stub-column tests performed on partially encased composite (PEC) columns made with welded H-section steel are described and presented. The H-section steel is stiffened with transverse link and concrete is poured between the flanges of the steel section. The axial comprehensive study has been conducted on all specimens to investigate the ultimate axial capacity of PEC columns. The failure of all columns is due to local buckling of the flanges along with concrete crushing. Closer link spacing improves the ductility of the columns; however, the measurements show that in general yielding do not occur before the peak load in the links. The additional longitudinal bars have no a remarkable effect to the strength of the composite columns. Finally, an equation is proposed to predict the ultimate axial capacity of the partially encased composite column.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.