Abstract

Convection heat transfer in a channel with 90° ribs and V-shaped ribs were studied experimentally and numerically. The results showed that both the 90° ribs and V-shaped ribs enhance the convection heat transfer compared with a flat wall without ribs, but the pressure drop also increases. The overall thermal/hydraulic performance of the V-shaped ribs is better than that of the 90° ribs. Numerical simulations using the SST k-ω turbulence model were used to investigate the thermal/hydraulic performance for six rib bed, the results indicated that the 45° V-shaped continuous ribs had the best thermal/hydraulic performance. Comparison of continuous ribs and interrupted ribs shows that the heat transfer with the V-shaped interrupted ribs is less than with the V-shaped continuous ribs, but this is reversed for the 90° ribs.