Abstract

Numerical study was conducted by using ABAQUS software to investigate two issues on spun pile connections. The issues are usage of non-shrinkage concrete infill cast inside hollow of pile and ductility. An experimental test was carried out to investigate the effect of two different concrete infill types which were common concrete fc’ 35 MPa and non-shrinkage concrete fc’ 54 MPa. A finite element model was validated against experimental test. The results were compared in terms of hysteresis curve, ductility, and performance level. Ductility is one of the important parameters to describe performance of spun pile connections under seismic load. There are different approaches to calculate ductility and this leads to four different ductility values. Hence, ductility of spun pile with concrete infill is in the range of 3.2 to 4.8. Behavior of spun pile with non-shrinkage concrete infill is slightly improved although the results were almost similar.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.