Abstract
In this work, the authors wanted to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. Experimental investigations were carried out for four heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend double tube, U-tube with turbulator, plain double tube and U-bend double tube working with two-phase flow conditions (air-water mixture). For these geometries, the values of pressure drop and heat flux were determined. The comparison of heat transfer efficiency was performed based on NTU-ε method. The computational fluid dynamics (CFD) technique was also employed to investigate the influence of coiled wire inserts and air bubbly injection at heat transfer, pressure drops and overall efficiency in double tube heat-exchangers. For this purpose, six configurations of heat exchangers were meshed and simulated at various flow conditions by using the CFD package Autodesk CFD 2016 (Students & Educators version).
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.