Abstract

The thermal behavior of cryogenic propellant tanks is crucial issue in the operation of cryogenic propulsion systems. Herein, ground experiments were conducted in a 600-mm-diameter cryogenic tank filled with liquid nitrogen. As pre-pressurants, gaseous helium and gaseous nitrogen (of the same species as the liquid), were used to investigate its effect in accordance with actual propulsion systems. The tank was sealed after pre-pressurization to observe the self-pressurization. The evaporation rate and heat flow in the tank were estimated based on pressure and temperature measurements. In addition, the axial liquid temperature distribution was obtained through the liquid draining from the tank bottom, and a thermal stratification model was developed. These results demonstrated that the type of pre-pressurant significantly affected the thermal behavior in the tank. A higher evaporation rate and higher liquid internal energy rise rate with a thicker thermal layer were observed in the helium pre-pressurization case. The lower nitrogen partial pressure in the helium case enhanced the vaporization and growth of the thermal layer. Estimation of the power balance in the tank demonstrated that not only the ullage but also the heat mass of the tank provided heat for the evaporation and thermal layer. The evaporation occurs mainly at the contact point between the tank skin and liquid surface. The nitrogen vapor rises in a thin layer along the tank skin because of buoyancy under nitrogen pre-pressurization; however, buoyancy is lower under helium pre-pressurization, and a radial vapor flow is probably produced from the contact point instead, leading to a higher heat flux to the liquid.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call