Abstract

A Stirling cooler for space use must have a 5–10 year service life. The primary limitation is the degradation of cooling performance by gas contaminants, such as H2O, CO, CO2, O2, and N2. If these gas contaminants freeze in the regenerator or the displacer’s clearance seal, they can block the helium flow for heat exchange or disturb the smooth movement of the displacer. This study verified the effect of adsorbent adapted for the 20 K-class two-stage Stirling (2ST) cooler with a correlation between the cooling performance and the residual concentration of CO2 gas contaminant. Although the 2ST cooler was stopped by a displacer stuck during initial cooling by adding CO2 at 4990 ppm, the cooling performance was finally recovered to a reference level below 20 K when the equipped adsorbent was activated. Gas analysis showed that the residual CO2 concentration was successfully reduced to 426 ppm, satisfying the less than 500 ppm requirement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.