Abstract
This paper presents a study on the structural behavior of traditional raw earthen masonry (adobe). Shear behavior and tensile strength are analyzed from diagonal compression and splitting tests. Consistent results of the tensile strength are obtained from splitting and diagonal compression tests. The assumption of a pure shear strain state in diagonal compression tests is validated from the analysis of the full strain field measured by using a Digital Image Correlation system. Different estimators for the shear modulus are analyzed. The authors recommend a tangent modulus value between 1/3 and 2/3 of the shear strength for structural design purpose. Results from previous research works are compared and analyzed. Values of tensile strength, shear modulus and the ratio tensile/compressive strength are in good agreement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.