Abstract

This study performed a comparison between experimental and computational fluid dynamic (CFD) simulation results of boiling heat transfer coefficient of R410A in a small tube. The experimental data were obtained in the horizontal circular tubes of 3.0[Formula: see text]mm inner diameter, the length of 3000[Formula: see text]mm including: mass flux and heat flux in a range from 300[Formula: see text]kg/m2s to 600[Formula: see text]kg/m2s and from 5[Formula: see text]kW/m2 to 10[Formula: see text]kW/m2, respectively, and the saturation temperature constantly kept at 20[Formula: see text]C. In the simulation procedure, the Eulerian multiphase with wall boiling were obtained. The effects of mass flux and heat flux on the heat transfer coefficient of R410A were analyzed. The comparative data between CFD and experiment was also illustrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.