Abstract
Abstract For larger containments and higher operation parameters, characteristics of the outside cooling of the PCCS are very important for the analysis on the containment integrity. A preliminary analysis was made and a four-step experimental method was used to numerically analyze the falling water film evaporation for the advanced passive containment. Then, the water flow stability along the outside wall of the containment was studied. The results fit well with those correlations without airflow when the air velocity is less than 5.0 m/s. However, when the air velocity is larger than 5.0 m/s, the influence of the air velocity on the water film will appear and the mean water film thickness will be thicker. Based on the prototype operation parameters, experimental studies were carried and the results were compared with the Dittus-Boelter correlation within the operation ranges. A modification factor was proposed for the conservative application of this correlation for nuclear safety analysis.