Abstract

Energy and exergy analysis of Pulverized Coal Fired Subcritical Power Plant (CFPP) performed to assess power plant performance and identify major losses both energy and exergy term. It’s found that, based on energy analysis, major losses occur in condenser, moisture in coal and steam turbine. While exergy analysis result that most exergy losses and destruction was in boiler and feedwater heater. Energy efficiency of boiler on 250MW, 300MW and 380MW was 68.56%, 69.56% and 72.42% respectively while exergetic efficiency was 52.81%, 56.33% and 57.39% respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.