Abstract

Exergy is based on the second law of thermodynamics and is the only rational basis for evaluating the system performance. The aim of this paper is to study in detail the irreversibilities in the steam-ejector refrigeration system. The influence of the cycle parameters is analysed on the basis of the first and second law and the results indicated the components with the greater irreversibility. A better quality of the ejector has more effect on the system performance than the better quality of other components, because the ejector at first and the condenser at second have the greater exergy loss of the system. For the refrigeration system the maximum coefficient of performance varying between 0.4 to 0.6 and the second law efficiency remains close to 0.17 for generator pressure 6 bar, condenser temperature 44–50°C and evaporator temperature 4–8°C. Also the study showed that the second law analysis quantitatively visualizes losses within a system and gives clear trends for optimization. Copyright © 2005 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.