Abstract

A multi-MHz laser absorption sensor at 777.2nm (12,863c m -1) is developed for simultaneous sensing of (1)O(5 S 0) number density, (2)electron number density, and (3)translational temperature at conditions relevant to high-speed entry conditions and molecular dissociation. This sensor leverages a bias tee circuit with a distributed feedback diode laser and an optimization of the laser current modulation waveform to enable temporal resolution of sub-microsecond kinetics at electronvolt temperatures. In shock-heated O 2, the precision of the temperature measurement is tested at 5MHz and is found to be within ±5% from 6000 to 12,000K at pressures from 0.1 to 1atm. The present sensor is also demonstrated in a CO:Ar mixture, in parallel with a diagnostic for CO rovibrational temperature, providing an additional validation across 7500-9700K during molecular dissociation. A demonstration of the electron number density measurement near 11,000K is performed and compared to a simplified model of ionization. Finally, as an illustration of the utility of this high-speed diagnostic, the measurement of the heavy particle excitation rate of O(5 S 0) is extended beyond the temperatures available in the literature and is found to be well represented by k(3 P→5 S 0)=2.7×10-14 T 0.5 exp⁡(-1.428×104/T)c m 3⋅s -1 from 5400 to 12,200K.