Abstract

Abstract The NO content of the gas-vapour phase of cigarette smoke is determined by a simple colourimetric procedure: NO is absorbed by a solution of FeSO4 in diluted H2SO4 up to an equilibrium with the formation of the addition compound Fe•NO•SO4. The spectrophotometric investigation of the resulting solution shows two maxima (580 and 445 mµ). The maximum at 445 mµ is chosen for the colourimetric determination of NO. The formation of Fe•NO•SO4 takes place via a reversible stoichiometric reaction, the absorption of NO is proportional to the partial pressure of NO in the gas mixture. The concentration of NO in the mainstream smoke of commercial cigarettes with different tobacco types and blends has been shown to be in the range between 250-1500 ppm, i.e. 110-660 µg NO/ cigarette. Contrary to other methods, the new procedure enables the differentiated determination of NO besides NO2. In the fresh smoke from Straight Virginia cigarettes, i.e. 2-5 sec. after generation, no NO2 was detectable. Under the same conditions, blended cigarettes showed a content of about 5 µg NO2/cigarette. 60 seconds after smoke generation, about 200 µg NO2/cigarette have been determined. These results show that of the nitrogen oxides only NO is present in fresh cigarette smoke. The autoxidation to NO2 occurs to a considerable extent within 60 seconds

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call