Abstract

Generally, the thermal conditions in simple flats for rent are still not within a comfortable range. There is no implementation of artificial ventilation (Air Conditioner) with adjustable air temperature, so passive strategies still need to be pursued. In this case, the strategy pursued is Direct Evaporative Cooling (DEC) system with cooling pads made from stove wicks. Experimental methods were conducted in one of the apartment buildings in Surabaya, namely Indrapura Walk-up Flat. The research results indicate that at relatively high outdoor air temperatures from 12:00 to 15:00 local time, ranging from 27.9 to 32oC, the implementation of DEC was able to reduce the air temperature by 1.94-2.08oC

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.