Abstract
Contact between a mobile elevating work platform (MEWP) and an energized overhead powerline (OHPL) is a warned-against event that is associated with damage to property as well as injury or death. The objective of this project was to evaluate the effectiveness of two different proximity warning devices (PWDs) installed on an MEWP operated near OHPLs. The general procedure used was to rotate the MEWP work platform horizontally away from, then toward, the OHPL from each side of the MEWP (at various platform heights), noting the distance between the MEWP and the OHPL when an alarm occurred. PWD2 allowed violation of the simulated OSHA boundary on 74.3% of the total rotations without initiating a warning alarm and was too sensitive to be practical as a startup alarm system. PWD1 did not allow operation of the MEWP within 20 feet of the actual OSHA minimum approach distance. The results of the startup test for PWD1 were no-where near consistent.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the National Academy of Forensic Engineers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.