Abstract

We assessed the performance of two new commercially available rapid diagnostic tests (RDTs) for malaria (SD Bioline Malaria Ag Pf test and Ag Pf/Pan test) in 200 patients with uncomplicated malaria between August and October 2007 in Madagascar. Results of the two RDTs were compared with those obtained by microscopy and real-time polymerase chain reaction. The sensitivity and specificity for detection of Plasmodium falciparum were 93% and 98.9%, respectively, for the SD Bioline Malaria Ag Pf test and 92.9% and 98.9% for the SD Bioline Malaria Ag Pf/Pan test. The sensitivity of the SD Bioline Malaria Ag Pf/Pan test was much lower for detection of other species (63.6%). The sensitivity of the two new assays decreased to 77.3% at parasitemia levels < 100 parasites/microL for detection of P. falciparum.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.