Abstract
Distal radius fractures are a common injury that is often reduced with percutaneous K-wires. The sensory nerves in this area are at risk of injuring from pin placement. Cadaveric studies of the nerve distribution patterns have elucidated certain safe zones for pin placement that limits the risk of sensory nerve injury. These studies have advocated a limited open technique that involves a shallow incision followed by blunt dissection to the bone before a k-wire is drilled into the radius. A previously identified safe zone in the anatomical snuffbox was evaluated in 40 cadaver wrists for k-wire placement via a percutaneous technique that involves putting the pin directly through the skin without an incision or blunt dissection. After k-wire placement each wrist was dissected and sensory nerve distribution relative to the pin placement was evaluated. The variability of the distribution of the sensory nerves, namely the lateral antebracheal cutaneous nerve and the superficial branch of the radial nerve, is such that no truly safe zone exists for pin placement with the percutaneous technique in this area.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.