Abstract

A total of 247 strains of streptococci isolated from humans were tested for identification in the Rapid Strep system. The identification rates and identification levels were different for each Streptococcus species. Our data indicate that the Rapid Strep system will identify nearly all the beta-hemolytic Streptococcus species if serological procedures are used in conjunction with the rapid physiological procedures. Of the group D streptococci, 98% of the enterococci and 95% of the non-enterococci were correctly identified. Of the commonly occurring viridans species, 85% were correctly identified, but only 10% of the less frequently occurring viridans species were identified. A total of 90% of the Streptococcus pneumoniae and 60% of the Aerococcus strains were correctly identified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.