This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was measured at a distance of 20, 30, and 60 cm from the accelerator target. It is shown that the experimental data correspond to the radiation field of a point cosine source with a relative error of 13%. The spatial distribution of the bremsstrahlung exposure dose of the Gamma-4 facility was reconstructed taking into account the spatial orientation of the irradiators. The bremsstrahlung exposure doses at a distance of 15 cm from the modules targets are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.