Abstract

The authors evaluated the potential for ocular damage from optical radiation emitted by Light Emitting Diode (LED) based lamps used for general illumination. Ten LED lamps were randomly selected off the shelf from a local home improvement store. The LEDs were behind diffusers in half of these lamps, while in the other half, the LEDs were clearly visible. In addition, a battery powered LED lantern having a LED source behind a diffuser was measured. The optical radiation emissions from two common incandescent lamps were also measured to compare the relative hazards of LED and incandescent lamps. All lamp samples were evaluated in accordance with procedures specified in the American National Standards Institute/Illuminating Engineering Society of North America (ANSI/IESNA) Standard RP-27.3. For comparison purposes, the lantern and 100 W incandescent lamps were also evaluated according to ANSI RP-27.1. These measurements indicate that no lamp evaluated poses any photobiological hazard, and therefore, all lamps fall in the RP-27.3 category of Exempt Group. However, when evaluated in accordance with RP-27.1, the 100 W incandescent lamp would be classified in Risk Group 1 (low risk), while the LED lantern would be classified in Risk Group 2 (moderate risk).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call