Abstract
Among future space missions, national aeronautics and space administration (NASA) selected two of them to analyze the diversity in organic content within Martian and Titan soil samples using a gas chromatograph – mass spectrometer (GC–MS) instrument. The Dragonfly space mission is planned to be launched in 2027 to Titan's surface and explore the Shangri-La surface region for years. One of the main goals of this mission is to understand the past and actual abundant prebiotic chemistry on Titan, which is not well characterized yet. The ExoMars space mission is planned to be launched in 2028 to Mars’ surface and explore the Oxia Planum and Mawrth Vallis region for years. The main objectives focus on the exploration of the subsurface soil samples, potentially richer in organics, that might be relevant for the search of past life traces on Mars where irradiation does not impact the matrices and organics. One recently used sample pre-treatment for gas chromatography – mass spectrometry analysis is planned on both space missions to detect refractory organic molecules of interest for astrobiology. This pre-treatment is called derivatization and uses a chemical reagent – called dimethylformamide dimethyl acetal (DMF-DMA) – to sublimate organic compounds keeping them safe from thermal degradation and conserving the chirality of the molecules extracted from Titan or Mars’ matrices. Indeed, the detection of building blocks of life or enantiomeric excess of some organics (e.g. amino acids) after DMF-DMA pre-treatment and GC–MS analyses would be both bioindicators. The main results highlighted by our work on DMF-DMA and Tenax®TA interaction and efficiency to detect organic compounds at ppb levels in a fast and single preparation are first that Tenax®TA did not show the onset of degradation until after 150 experiments – a 120 h at 300 °C experiment – which greatly exceeds the experimental lifetimes for the DraMS and GC-space in situ investigations. Tenax®TA polymer and DMF-DMA produce many by-products (about 70 and 46, respectively, depending on the activation temperature). Further, the interaction between the two leads to the production of 22 additional by-products from DMF-DMA degradation, but these listed by-products do not prevent the detection of trace-level organic molecules after their efficient derivatization and volatilization by DMF-DMA in the oven ahead the GC–MS trap and column.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.